launching — first Atlanta meetup this fall, join the list free worksheets — prompt engineering, computer vision, ML metrics for companies — team training and event sponsorship NVIDIA-certified — generative-AI workshops in partnership with NVIDIA open source — RocketRAG, UMIE, LOMA on GitHub, contributors welcome

← All projects

Predicting Catheter-Induced Coronary and Aortic Injuries Using Machine Learning

Machine learning models that predict catheter-induced coronary and aortic dissections from clinical, anatomical, and procedural data across more than 80,000 catheterized patients.

cardiologyrisk-predictionmachine-learningxgboost
Diagram for Catheter Injury Prediction

Overview

In this study we developed and evaluated machine learning models to predict catheter-induced coronary and aortic dissections (CID) based on clinical, anatomical, and procedural data from more than 80,000 catheterized patients.

Dataset and Cohort

We retrospectively analyzed 84,223 diagnostic and interventional coronary procedures performed between 2000 and 2022 at two high-volume cardiac centers. From these, 124 confirmed cases of CID were identified and adjudicated by expert reviewers, with non-catheter-related dissections excluded. Each case included detailed demographics, comorbidities, procedural data, and angiographic features, categorized using the NHLBI and Dunning classifications.

Variables and Modeling

Anatomical variables (small or stenotic ostium, atypical coronary origin, chronic total occlusion), procedural variables (guiding catheter use, radial vs. femoral access, target vessel), and clinical variables (hypertension, prior PCI, acute MI, chronic renal failure, COPD, and others) were used. Given the very low event rate (0.147%), class imbalance was addressed with SMOTE, the data was split 70/30, and three-fold cross-validation ensured stable estimates. Six algorithms — Logistic Regression, Decision Tree, Random Forest, Naive Bayes, KNN, and XGBoost — were trained in Python using sklearn, xgboost, imbalanced-learn, and dalex.

Results

The incidence of CID was 0.147% overall, with aortic involvement in 0.023%. Key procedural correlates were guiding catheter use (84% of cases), radial access (80%), and PCI procedures (84%). XGBoost achieved the best balance between precision (0.748) and recall (0.363), with an F1-score of 0.488, outperforming the other algorithms on the metrics that matter most for not missing true positives.